A Comparative Study on Mechanical Heart Valve and Bio-Prosthetic Valve

Authors(4) :-Dr. Anitha S, Hemanth Kumar G, Anarghya. K. S, Chandana. B. G

Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used, and important factors that affect the performance of mechanical heart valves and bio prosthesis valves.

Authors and Affiliations

Dr. Anitha S
Assistant Professor, Department of Biomedical Engineering, Adhiyamaan College of Engineering (Autonomous), Dr. M. G. R. Nagar, Hosur, Tamil Nadu, India
Hemanth Kumar G
US Scholar, Department of Biomedical Engineering, Adhiyamaan College of Engineering (Autonomous), Dr. M. G. R. Nagar, Hosur, Tamil Nadu, India
Anarghya. K. S
US Scholar, Department of Biomedical Engineering, Adhiyamaan College of Engineering (Autonomous), Dr. M. G. R. Nagar, Hosur, Tamil Nadu, India
Chandana. B. G
US Scholar, Department of Biomedical Engineering, Adhiyamaan College of Engineering (Autonomous), Dr. M. G. R. Nagar, Hosur, Tamil Nadu, India

Mechanical Heart Valves, Bio Prosthesis Valves, Valve Design, Valve Performance.

  1. Developments in mechanical heart valve prosthesis KALYANI NAIR, C V MURALEEDHARAN and G S BHUVANESHWAR Biomedical TechnologyWing, Sree Chitra Tirunal Institute for Medical Sciences & Technology, Thiruvananthapuram 695 012, India
  2. Mechanical versus bioprosthetic aortic valve replacement Stuart J. Head*, Mevlu¨t C¸elik, and A. Pieter Kappetein Department of Cardiothoracic Surgery, Erasmus University Medical Centre, Dr Molewaterplein 40, 3015 GE Rotterdam, The Netherlands
  3. Mechanical Heart Valves: 50 Years of Evolution Vincent L. Gott, MD, Diane E. Alejo, and Duke E. Cameron, MD Division of Cardiac Surgery, The Johns Hopkins Medical Institutions, Baltimore, Maryland
  4. Morse D, Steiner RM, Fernandez J, eds. Guide to prosthetic cardiac valves. New York: Springer-Verlag, 1985.
  5. DeWall RA, Qasim N, Carr L. Evolution of mechanical heart valves. Ann Thorac Surg 2000;69:1612-21.
  6. Grunkemeier GL, Li H, Naftel DC, Starr A, Rahimtoola SH. S2238 GIBBON’S HEART-LUNG MACHINE GOTT ET AL Ann Thorac Surg MECHANICAL HEART VALVE EVOLUTION 2003;76:S2230-9 Long-term performance of heart valve prosthesis. Curr Probl Cardiol 2000;25:78-154.
  7. Hufnagel CA. Aortic plastic valvular prosthesis. Bull Georgetown Univ Med Center 1951;5:128-30.
  8. Harken DE. The emergence of cardiac surgery: personal reflection of the 1940s and 1950s. J Thorac Cardiovasc Surg 1989;98:805-13.
  9. A. Vahanian, H. Baumgartner, J. Bax et al., “Guidelines on the management of valvular heart disease: the task force on the management of valvular heart disease of the European society of cardiology,” European Heart Journal, vol. 28, no. 2, pp. 230-268, 2007.
  10. R. F. Siddiqui, J. R. Abraham, and J. Butany, “Bioprosthetic heart valves: modes of failure,” Histopathology, vol. 55, no. 2, pp. 135-144, 2009.
  11. L. H. Edmunds, R. E. Clark, L. H. Cohn, G. L. Grunkemeier, D. C.Miller, and R. D.Weisel, “Guidelines for reportingmorbidity and mortality after cardiac valvular operations,” Annals of Thoracic Surgery, vol. 62, no. 3, pp. 932-935, 1996.
  12. X. Y. Jin, K. Dhital, K. Bhattacharya, R. Pieris, N. Amarasena, and R. Pillai, “Fifth-year hemodynamic performance of the Prima stentless aortic valve,” Annals ofThoracic Surgery, vol. 66, no. 3, pp. 805-809, 1998.
  13. J. P. Gott,M.N.Girardot, J.M. D. Girardot et al., “Refinement of the alpha aminooleic acid bioprosthetic valve anticalcification technique,” Annals ofThoracic Surgery, vol. 64, no. 1, pp. 50-58, 1997.
  14. Horstkotte D, Bodnar E 1991 Bileaflet valves. In Replacement CardiacValves (eds) E Bodnar, R Frater (Toronto: Pergamon) 9: 201-228
  15. Cohn, G. L. Grunkemeier, D. C.Miller, and R. D.Weisel, “Guidelines for reportingmorbidity and mortality after cardiac valvular operations,” Annals of Thoracic Surgery, vol. 62, no. 3, pp. 932-935, 1996.
  16. X. Y. Jin, K. Dhital, K. Bhattacharya, R. Pieris, N. Amarasena, and R. Pillai, “Fifth-year hemodynamic performance of the Prima stentless aortic valve,” Annals ofThoracic Surgery, vol. 66, no. 3, pp. 805-809, 1998.
  17. J. P. Gott,M.N.Girardot, J.M. D. Girardot et al., “Refinement of the alpha aminooleic acid bioprosthetic valve anticalcification technique,” Annals ofThoracic Surgery, vol. 64, no. 1, pp. 50-58, 1997.
  18. Horstkotte D, Bodnar E 1991 Bileaflet valves. In Replacement CardiacValves (eds) E Bodnar, R Frater (Toronto: Pergamon) 9: 201-228
  19. Bhuvaneshwar G S, Muraleedharan C V, Ramani A V, Valiathan M S 1991 Evaluation of materials for artificial heart valves. Bull. Mater. Sci. 14: 1361-1374.
  20. Koertke H, Zittermann A, Wagner O, Secer S, Christ Of H, Sciangula A, Saggau W, Sack FU, Ennker J, Cremer J, Musumeci F, Gummert JF. Telemedicineguided, very low-dose international normalized ratio self-control in patients with mechanical heart valve implants. Eur Heart J 2015;36:1297-1305.
  21. Bottio T, Casarotto D, Thiene G, Caprili L, Angelini A, Gerosa G. Leaflet escape in a new bileaflet mechanical valve: TRI technologies. Circulation 2003;107:2303-2306.
  22. Akins CW, Miller DC, Turina MI, Kouchoukos NT, Blackstone EH, Grunkemeier GL, Takkenberg JJ, David TE, Butchart EG, Adams DH, Shahian DM, Hagl S, Mayer JE, Lytle BW. Guidelines for reporting mortality and morbidity after cardiac valve interventions. Eur J Cardiothorac Surg 2008;33:523-528.
  23. Jamieson WR, Ling H, Burr LH, Fradet GJ, Miyagishima RT, Janusz MT, Lichtenstein SV. Carpentier-Edwards supraannular porcine bioprosthesis evaluation over 15 years. Ann Thorac Surg 1998;66:S49-S52.
  24. Siddiqui RF, Abraham JR, Butany J. Bioprosthetic heart valves: modes of failure. Histopathology 2009;55:135

Publication Details

Published in : Volume 5 | Issue 5 | March-April 2020
Date of Publication : 2020-03-05
License:  This work is licensed under a Creative Commons Attribution 4.0 International License.
Page(s) : 23-30
Manuscript Number : EBHAC028
Publisher : Technoscience Academy

Print ISSN : 2395-6011, Online ISSN : 2395-602X

Cite This Article :

Dr. Anitha S, Hemanth Kumar G, Anarghya. K. S, Chandana. B. G, " A Comparative Study on Mechanical Heart Valve and Bio-Prosthetic Valve", International Journal of Scientific Research in Science and Technology(IJSRST), Print ISSN : 2395-6011, Online ISSN : 2395-602X, Volume 5, Issue 5, pp.23-30, March-April-2020.
Journal URL : https://ijsrst.com/EBHAC028
Citation Detection and Elimination     |      | | BibTeX | RIS | CSV

Article Preview