Zincon, a metal ion indicator, has been polymerised on the graphite electrode to get a poly zincon film  modified electrode. The formation of the polymer film (PZF)was confirmed by optical microscopis studies. The PZF modified electrode was characterised by the cyclic voltammetry, square wave voltammetry and chronoamperometry. The experimental parameters influencing the electrochemical behaviour of the PZF modified electrode such as pH and scan rates in presence of dopamine were optimised. The modified electrode showed excellent sensitivity and stability towards the electrocatalytic oxidation of dopamine. The determination range for dopamine was found to be 1.16 to 401µM with a correlation coefficient (R2) of 0.997. The limit of detection for the determination of Dopamine was 0.38 µM. The proposed method was used for the determination of dopamine in pharmaceutical preparations.

References

  1. Chunyan Deng, Jinhua Chen, Mengdong Wang, Chunhui Xiao, Zhou Nie, Shouzhuo Yao, Biosensors and Bioelectronics, 24 (2009) 2091.
  2. De-Qian Huang, Cheng Chen, Yi-Ming Wu, Hong Zhang, Liang-Quan Sheng1, Hua-Jie Xu, and Zhao-Di Liu, Int. J. Electrochem. Sci., 7 (2012) 5510 .
  3. Hua-Jun Qiu, Gui-Ping Zhou, Guang-Lei Ji, Yun Zhang, Xi-Rong Huang, Yi Ding, Colloids and Surfaces B: Biointerfaces, 69 (2009) 105.
  4. D. Amin, Analyst, 111 (1986) 257.
  5. C.S. Sastry, V.G. Das, K.E. Rao, Analyst, 110 (1985) 398.
  6. S. Wang, L. Du, L. Wang, H. Zhuang, Anal. Sci., 20 (2004) 317.
  7. Reza Karimi Shervedani, Mojtaba Bagherzadeh, Seyed Ahmad Mozaffari, Sensors and Actuators B, 115 (2006) 621.
  8. De-Qian Huang, Cheng Chen, Yi-Ming Wu, Hong Zhang, Liang-Quan Sheng, Hua-Jie Xu, and Zhao-Di Liu, Int. J. Electrochem. Sci., 7 (2012) 5520.
  9. Haesang Jeong and Seungwon Jeon, Sensors, 8 (2008) 6935.
  10. Kannika Keawkima, Suchada Chuanuwatanakula, Orawon Chailapakula, Shoji Motomizuc, Food Control, 31 (2013) 14.
  11. E. Merino and M. Ribagorda, Beilstein J. of Org. Chem., 8 (2012) 1071.
  12. M. Haro, I. Gascon, R. Aroca, M. C. Lopez and F. M. Royo, J. of Colloid and Int. Sci., 319 (2008) 277.
  13. E. Kibena, U. Maorg, L. Matisen, P. Sulamagi and K. Tammeveski, J. of Electroanal. Chem., 686 (2012) 46.
  14. T. Ikeda and O. Tsutsumi, Science, 268 (1995) 1873.
  15. Y. R. Leroux and P. Hapiot, Electrochem. Commun., 33 (2013) 107.
  16. J. A. Delaire and K. Nakatani, Chemical Reviews, 100 (2000) 1817.
  17. F.scholz and B.Lange, Trends Anal.Chem., 11 (1992) 359.

Downloads

Published

2018-02-28

Issue

Section

Research Articles

How to Cite

[1]
S. Vasanthi, K. Krishna Kumar, S. Sriman Narayanan, " An Amperometric Sensor for the Determination of Dopamine Using Poly Zincon Film Modified Electrode, International Journal of Scientific Research in Science and Technology(IJSRST), Online ISSN : 2395-602X, Print ISSN : 2395-6011, Volume 4, Issue 2, pp.751-757, January-February-2018.