A Non- Invasive Blood Pressure Measurement Using Embedded Technology

Authors

  • K.Y. Rokde  Assistant Professor, Department of Electronics,K.R.Pandav Mahavidyalaya, Nagpur, Maharashtra, India
  • P.B.Dahikar  Associate Professor, Department of Electronics, Kamla Nehru College, Nagpur, Maharashtra, India
  • S.S.Shende  Assistant Professor, Department of Electronics, Shivaji Science College, Nagpur, Maharashtra, India
  • S.M.Ghatole  
  • M. J. Hedau  

Keywords:

Blood Pressure, Wireless, Non-invasive, monitoring system etc.

Abstract

A Health care is one of the fast emerging fields today. With the average age of general population increasing each year the credit goes to cutting edge of medical research. New methods are developed almost every month to as a solution to numerous health problems for which accurate diagnosis is the need of the day. The Biomedical equipment provides accurate reproduction of body signals and automated diagnosis and patient monitoring systems. The field of biomedical instrumentation is an integral part of medical research. Sometimes it becomes necessary to monitor physiological events from a distance like monitoring a patient in an ambulance and in other applications away from the hospital, collection of medical data from a home or office and use of telephone links for transmission of medical data. In this research work it is to study the Non- Invasive Blood Pressure Measurement of patients using embedded technology which has the low cost, reliable, and portable and it is used in many medical laboratories and industries. In present development, the real time blood pressure biomedical signal is measured using an optical measurement circuit based plethysmography technique(PPG) contineously for a long period of time.The detected measured signal amplified using an operational amplifier circuit and interface with the microcontroller. The numerical reading values of systolic and distolic blood pressure remotely recorded and displayed with the help of LCD and stationary computer.

References

  1. Ayala Kenneth  J."The 8051 Microcontroller", Published By Penram International (India), Second we3
  2. Dougherty  Kelvin  M.," Analog To Digital Conversion" A Practical Approach, Mc-Graw  Hill, Inc.
  3. Hall D.V,"Microprocessor & Interfacing Programming Hardware", Tata Mc-Grow-Hill Edition, 1991, Seventh Reprint1995.
  4. Mazidi Muhammad Ali, Mazidi Janice Gillispie,"The 8051 Microcontroller And Embedded Systems" Published By Pearson Education (Singapore) Pvt. Ltd, First Edition
  5. Gurnule W B,; Dhote S S,; Pharma   J. Der Chemica,; 4(2): 791,2012
  6. Khan, F. and Bilgainya, R.,  Synthesis and characterization of    metal and metal oxide  sponges  using Triton X-165 as sacrificial        template. Indian J. Chem. A, 2011,  55–59.
  7. S.S.Shende, P.B.Dahikar2, MJ.Hedau3, K.Y. Rokde4 International Journal of Innovative Research in Computerand Communication Engineering(An ISO 3297: 2007 Certified Organization)Vol. 2, Issue 1, January 2014 p-p 2626-2631
  8. M. J. Hedau, M. P. Dhore, P. B. Dahikar, "Application of Wireless Signal Simulation Via Cell-Phone "International Conference on circuit system and simulation, , pp. 92–95, Vol.7, IACSIT Press, Singapore, 2011
  9. M. J. Hedau, M. P. Dhore, P. B. Dahikar, "Application of Microcontroller in Technical communication"International Journal of ETA and ETS, IACSIT ISSN No 0974- 3588Vol.5Issue 1,2012.
  10. P. B. Dahikar M. J. Hedau, S. C. Moholkar "Application of Microcontroller in Receiving Unit of the Technical Communication"International Journal of ETA and ETS, IACSIT  ISSN No 0974-3588 Vol.5 Issue 2, 2012.
  11. K.Y.Rokde, Dr. P.B.Dahikar2, Dr. M.J.Hedau3, S.S.Shende 4 International Journal of Innovative Research in Computer and Communication Engineering(An ISO 3297: 2007 Certified Organization)Vol. 2, Issue 9, September  2014 p-p 2320-9798.
  12. K.Y.Rokde, Dr. P.B.Dahikar, Dr. M.J.Hedau, S.S.Shende, "An Embedded System for  Device Control System with Telephone Answering Machine", International Journol of  Researches in Social Sciences and Information Studies IJRSSIS, Vol. 2, Issue 3, ISBN  No-2347-8268, September 2014.
  13. Md. Shamsul Arefin, Tajrian Mollick," International Journal of Scientific & Engineering  Research", ISSN 2229-5518, Volume 4, Issue3, March-2013, IJSER 2013.
  14. Basem Abu Zneid1, Mohammed Al-zidi1, Tareq Al-kharazi," IEEE region 10 symposium,"april 2014,PP- 248-253, Kaula Lumpur, Malaysia.
  15. Rokde K Y, Shende S. S, Ghatole S M, Dahikar P B, "International Journal of  Electronics, Communication and soft computing science and Engineering- IJECSCSE", PP No-1-4, vol 1, issue 1, 2015.

Downloads

Published

2018-01-30

Issue

Section

Research Articles

How to Cite

[1]
K.Y. Rokde, P.B.Dahikar, S.S.Shende, S.M.Ghatole, M. J. Hedau, " A Non- Invasive Blood Pressure Measurement Using Embedded Technology, International Journal of Scientific Research in Science and Technology(IJSRST), Online ISSN : 2395-602X, Print ISSN : 2395-6011, Volume 4, Issue 1, pp.137-141, January-February-2018.