Comparative Study on the Analysis of Commercial Building with and Without Shearwall by Using ETABS
Keywords:
Base Shear, Response Spectrum Method, Shear Wall, Static MethodAbstract
In the seismic design of buildings, reinforced concrete structural wall, or shear wall, acts as a major earthquake resisting member. Structural walls provide an efficient bracing system and offer great potential for lateral load resistance. Shear wall systems are one of the most commonly used lateral-load resisting systems in high-rise buildings. Shear walls have very high in-plane stiffness and strength, which can be used to simultaneously resist large horizontal loads and support gravity loads, making them quite advantageous in many structural engineering applications. The properties of these seismic shear walls dominate the response of the buildings, and therefore, it is important to evaluate the seismic response of the walls appropriately. In this study the main focus is to compare the dynamic responses of frame structure with and without shear wall. Two models are generated with and without shear wall.G+18 R-C frame model with and without shear walls are generated with varying structural member dimensions according to height. The models are analysed by Static Method and Response Spectrum Method considering seismic zone II in ETABS2015. Parameters like lateral displacement, story drift, base shear and mode shapes are determined for all the models (with and without shear walls) by the two methods and are compared and the effectiveness of shear walls is enumerated. Also, comparisons are made based on some studies previously done by the other authors.
References
- U.HVarnayi in his second edition of “Design of structures"
- S.KDuggal in his"Earth quake resistant design of structures" Page no:301 ,8.12 about Shear walls.
- S.KDuggal in his"Earth quake resistant design of structures"pg.no:305 on flexural strength 8.14.1 case:1, case:2.
- S.KDuggal in his"Earth quake resistant design of structures" 8.16 Design of Shear walls which is also given in Is code 13920:1993
- Mr A.PJadhav Associate Professor Rajarambapu Institute of technology rajaramnagar,
- Islampur has given a detailed report on the form work used for the construction of shear walls.
- A report on effects of openings in shear walls on seismic response of structure by sharminriza chowdhary, department of civil engineering dhake-1208, Bangladesh mostly focused on the design of shear walls with openings on seismic response using Etabs
- I.S 456:2000 As per clause 32, design for wall describes, design of horizontal shear in clause 32.4 given details of how shear wall have to be constructed.
Downloads
Published
Issue
Section
License
Copyright (c) IJSRST