Analysis of Image Quality and Radiation Dose in Lumbar and Pelvic Examination Using the Copy Image Feature : A Phantom Study

Authors

  • Abdul Gamal S  Department of Diagnostic Imaging and Radiotherapy, STIKES Pertamedika Jakarta, Indonesia
  • Tri Asih Budiati  Department of Diagnostic Imaging and Radiotherapy, STIKES Pertamedika Jakarta, Indonesia and Radiographer, Pertamina Central Hospital, Jakarta, Indonesia
  • Muhammad Irsal  Department of Diagnostic Imaging and Radiotherapy, Poltekkes Kemenkes Jakarta II, Jakarta, Indonesia
  • Ardilah Ramadhani  Department of Diagnostic Imaging and Radiotherapy, STIKES Pertamedika Jakarta, Indonesia
  • Hamdi Rubiyanto  Department of Diagnostic Imaging and Radiotherapy, STIKES Pertamedika Jakarta, Indonesia
  • Alvin Raihan  Radiographer, Pertamina Central Hospital, Jakarta, Indonesia

DOI:

https://doi.org/10.32628/IJSRST52411117

Keywords:

Dose Area Product (DAP), Exposure Index, Radiation Protection

Abstract

Copy image is a software feature that is capable of duplicating images. So it can reduce errors in overexposure in patients. The purpose is to analyze feature usage images on radiation dose and image quality in lumbar and pelvic radiographic examinations. This research method uses quantitative with an experimental approach and research review. This research was carried out at Pertamina central Hospital Jakarta in February – March 2023 with the tools and materials used: X-ray multipurpose, computer radiography, and phantom anthropomorphic. For radiation dose, use the calculated value does area product (DAP), while for radiographic image quality use the range indicator exposure index (EI). The analysis carried out was comparing the use of copy images on radiation dose and image quality in lumbar and pelvic examinations. Results of using features copy image show a higher radiation value than examining the lumbar and pelvis separately one by one, while for image quality the value exposure index shows optimal indicators. Radiographers are expected to be wiser in implementing radiation protection when using procedures to copy images by minimizing the area of the collimation field.

References

  1. Ujang Wiharja and Abdul Kodir Al Bahar, 'Analisa Uji Kesesuaian Pesawat Sinar-X Radiografi,' Prosiding Seminar Nasional Sains dan Teknologi , vol. 0, no. 0, Nov. 2019, Accessed: Jun. 11, 2023. [Online]. Available: https://jurnal.umj.ac.id/index.php/semnastek/article/view/5166
  2. M. Irsal, M. Mayarani, B. Suroso, M. Ichsan, and A. Yansyah, 'Improving Radiographer Understanding Of Diagnostic Reference Level AS An Effort To Optimize Radiographic Examination,' Journal of Health, vol. 8, no. 1, pp. 1–10, Jan. 2021, doi: 10.30590/JOH.V8I1.200.
  3. M. Irsal, E. Hidayanto, and Z. Arifin, 'Analisa Pengaruh Faktor Eksposi Terhadap Entrance Surface Air Kerma (ESAK),' Youngster Physics Journal. Accessed: Jun. 11, 2023. [Online]. Available: https://ejournal3.undip.ac.id/index.php/bfd/article/view/7065/6834
  4. S. Sugiarti, S. Surip, and M. Fadila, 'Optimasi Faktor Eksposi pada Pemeriksaan Radiografi Thorax menggunakan Computed Radiography,' Jurnal Surya Medika (JSM), vol. 6, no. 1, pp. 52–56, Aug. 2020, doi: 10.33084/JSM.V6I1.1543.
  5. S. Rosidah, A. Soewondo, and S. M. Adi, 'Optimasi Kualitas Citra Radiografi Abdomen Berdasarkan Body Mass Indexdan Tegangan Tabung pada Computed Radiography,' Jurnal Epidemiologi Kesehatan Komunitas. Accessed: Jun. 11, 2023. [Online]. Available: https://ejournal2.undip.ac.id/index.php/jekk/article/view/5866/3754
  6. P. J. O'Connor et al., 'Reporting requirements for skeletal digital radiography: comparison of soft-copy and hard-copy presentation.,' https://doi.org/10.1148/radiology.207.1.9530323, vol. 207, no. 1, pp. 249–254, Apr. 1998, doi: 10.1148/RADIOLOGY.207.1.9530323.
  7. G. D. Roberts and J. P. Graham, 'Computed Radiography,' Veterinary Clinics of North America: Equine Practice, vol. 17, no. 1, pp. 47–61, Apr. 2001, doi: 10.1016/S0749-0739(17)30074-3.
  8. J. Wesly Manik, B. Hariyanto, and E. Abdullah, 'Analisis Kesesuaian Lapangan Kolimasi Pada Alat Digital Radiografi,' Cerdika: Jurnal Ilmiah Indonesia. Accessed: Jun. 11, 2023. [Online]. Available: https://cerdika.publikasiindonesia.id/index.php/cerdika/article/view/100/214
  9. P. I. Wulandari, 'Exposure Index (EI)Sebagai Alat Optimisasi Pada Sistem Radiografi Digital: Implementasi dan Tantangan Bagi Radiografer,' JRI (Jurnal Radiografer Indonesia), vol. 6, no. 1, pp. 1–10, May 2023, doi: 10.55451/JRI.V6I1.167.
  10. P. I. Wulandari, P. O. Agnesia, P. Oky Agnesia, I. W. G. Ari Mahardika, N. P. Meilani, and N. P. A. T. Dinda, 'Evaluasi Nilai Deviation Index pada Pemeriksaan Radiografi: Proporsi Overexposure Dan Underexposure Melebihi Citra Optimal,' Jurnal Ilmu Kedokteran dan Kesehatan, vol. 10, no. 2, pp. 1517–1523, Mar. 2023, Accessed: Jun. 11, 2023. [Online]. Available: https://ejurnalmalahayati.ac.id/index.php/kesehatan/article/view/9213
  11. J. Guðjónsdóttir, K. E. Paalsson, and G. P. Sveinsdóttir, 'Are the target exposure index and deviation index used efficiently?,' Radiography, vol. 27, no. 3, pp. 903–907, Aug. 2021, doi: 10.1016/J.RADI.2021.02.012.
  12. Q. B. Carroll, 'Radiography in the digital age : physics, exposure, radiation biology', Accessed: Jun. 12, 2023. [Online]. Available: https://books.google.com/books/about/RADIOGRAPHY_IN_THE_DIGITAL_AGE.html?hl=id&id=foW6CAAAQBAJ
  13. E. Seeram, 'Digital Radiography: Physical Principles and Quality Control, Second Edition,' Digital Radiography: Physical Principles and Quality Control, Second Edition, pp. 1–227, Jan. 2019, doi: 10.1007/978-981-13-3244-9/COVER.
  14. R. J. Patel, 'Digital Radiography Applications,' e-Journal of Nondestructive Testing, vol. 11, no. 02, Feb. 2006, Accessed: Jun. 11, 2023. [Online]. Available: https://www.ndt.net/search/docs.php3?id=3272
  15. E. Seeram, 'The New Exposure Indicator for Digital Radiography,' J Med Imaging Radiat Sci, vol. 45, no. 2, pp. 144–158, Jun. 2014, doi: 10.1016/J.JMIR.2014.02.004.
  16. M. L. Nurrokhim, D. Rochmayanti, and A. Budiono, 'Standarisasi Indeks Eksposur untuk Memenuhi Kriteria Anatomi dan Aspek Teknis pada Radiografi Thorax Pediatrik,' Jurnal Imejing Diagnostik (JImeD), vol. 7, no. 1, pp. 22–27, Feb. 2021, Accessed: Jun. 11, 2023. [Online]. Available: https://ejournal.poltekkes-smg.ac.id/ojs/index.php/jimed/article/view/5937
  17. A. Dwi Prastanti, B. Abimanyu, A. N. Kurniawan, and S. N. Baiti, 'Optimasi Citra CR dan Limitasi Dosis Radiasidengan Pengaturan Kolimasi Pada Radiograf Cervical,' Jurnal Imejing Diagnostik (JImeD), vol. 8, no. 1, pp. 35–39, Feb. 2022, Accessed: Jun. 11, 2023. [Online]. Available: https://ejournal.poltekkes-smg.ac.id/ojs/index.php/jimed/article/view/8259
  18. S. Asriningrum, 'Efek Perubahan Dosis Radiasi Dan Kualitas Gambar Pada Hasil Radiograph Dengan Luas Kolimasi Berbeda,' Jurnal Imejing Diagnostik (JImeD), vol. 6, no. 2, pp. 103–106, Jul. 2020, Accessed: Jun. 11, 2023. [Online]. Available: https://ejournal.poltekkes-smg.ac.id/ojs/index.php/jimed/article/view/5772
  19. L. Lança and A. Silva, 'Digital imaging systems for plain radiography,' Digital Imaging Systems for Plain Radiography, vol. 9781461450672, pp. 1–161, Jun. 2013, doi: 10.1007/978-1-4614-5067-2/COVER.
  20. D. Rochmayanti, D. Darmini, and M. Jannah, 'Faktor Determinan Kolimasi,Ukuran Imaging Plate dan Delay Time Processing Terhadap Exposure Index,' Jurnal Riset Kesehatan. Accessed: Jun. 11, 2023. [Online]. Available: https://ejournal.poltekkes-smg.ac.id/ojs/index.php/jrk/article/view/2910/578

Downloads

Published

2024-02-29

Issue

Section

Research Articles

How to Cite

[1]
Abdul Gamal S, Tri Asih Budiati, Muhammad Irsal, Ardilah Ramadhani, Hamdi Rubiyanto, Alvin Raihan "Analysis of Image Quality and Radiation Dose in Lumbar and Pelvic Examination Using the Copy Image Feature : A Phantom Study" International Journal of Scientific Research in Science and Technology(IJSRST), Online ISSN : 2395-602X, Print ISSN : 2395-6011,Volume 11, Issue 1, pp.181-187, January-February-2024. Available at doi : https://doi.org/10.32628/IJSRST52411117