Experimental Study of Torsional Effect on Flat Plate used in Built-up Column Section
Keywords:
Built up Column, Flat Plate, Torsion, FEM (Finite element method) ABAQUS.Abstract
The built-up columns are widely used in the field of steel industries. The built up columns are extensively used as a compression members in truss, roofing, industries and elevated steel water tanks etc. The lacing and batten are the main components of built up column, the steel flat plate are mainly used as lacing and battens in built up columns. The structural behaviour of steel column and its stability are studied by many researchers. When the loading is eccentric to the column and are fixed in bottom and moment at top so that the column undergoes the torsion forces and the twisting moment directly impacts on lacing and battens of column. This paper present the torsional behaviour of flat plate use in built up column, it show the torsional effect on flat plate by experimental and analytical modelling in ABAQUS 6.13.
References
- Abaqus software 6.13 (finite element modelling).
- Diptiranjan SAHOO and Durgesh C. RAI. “Battened built-up beam-columns under cyclic loads” 13th World Conference on Earthquake Engineering, (2004).
- IS 800: 2007 General Constructions in steel code practice (third edition) INDIAN STANDARD.
- Mr. Rajkumar D. Patil, Prof. P. N. Gore. “Review the Effect of specimen geometry on torsion result” International Journal of Innovative Research in Science, Engineering and Technology (An ISO 3297: 2007 Certified Organization) (2013).
- O. Isler. “Seismic Performances and Typical Damages of Beam-Column Joints in the Rc Buildings” The 14th World Conference on Earthquake Engineering (October 12-17, 2008).
- Rajkumar.D.Patil, Purushottam.N.Gore. “Optimization of Hollow Specimen Dimensions in Torsion Testing of AISI 1020 Steel using Grey Relational Analysis” International Journal for Scientific Research & Development, (2016).
- Rajkumar D. Patil, Purushottam N. Gore. “Analysis of Specimen Dimensions in Torsion Testing of AISI 1020 Steel using Single Objective Taguchi Method and Multi Objective Grey Relational Analysis” Asian Review of Mechanical Engineering, (2017).
- Sophia C. Ale, Mohammadreza Vafaei. “A Numerical Study on the Seismic Performance of Built-Up Battened Columns” World Academy of Science, Engineering and Technology International Journal, (2017).
- Vasile-Mircea Venghiac, Mihail Stascov. Beam-to-Column Connections with Demountable Energy Dissipative Plates” 07 March (2018).