Analysis of Radiation Dose Rate and Evaluation of Whole Body Scan SPECT/CT Images in Thyroid Carcinoma Radioablation Patients Using Radioisotope 131I

Authors

  • Indah Maulidina Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang, Indonesia Author
  • Zaenal Arifin Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang, Indonesia Author
  • Zaenul Muhlisin Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang, Indonesia Author
  • M. Roeslan Abdul Gani Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang, Indonesia Author
  • Junan Imaniar Pribadi Nuclear Medicine Department Radiodiagnostic Installation, Dharmais Cancer Hospital, Jl. Letjen S. Parman No.84-86, Jakarta Barat, DKI Jakarta, Indonesia Author

DOI:

https://doi.org/10.32628/IJSRST24114115

Keywords:

Radioablation Therapy, Whole Body Scan 131I, Radiation Dose Rate

Abstract

The incidence rate of thyroid carcinoma shows an increasing trend from year to year. One method for treating thyroid carcinoma is radioablation therapy using 131I. The use of 131I must be carried out in accordance with radiation safety regulations to avoid undesirable radiation dose rates. Therefore, research was conducted to analyze the radiation dose rate emitted by patients, obtain the relationship between body mass index (BMI) and the emitted dose rate, and evaluate whole body scan images of Single-Photon Emission Computed Tomography (SPECT/CT) of thyroid carcinoma radioablation patients. The research was carried out by measuring the patient's radiation dose rate using a surveymeter. The sample used was 53 patients who met the inclusion criteria and were not included in the exclusion criteria. The patient is isolated until it is safe to leave the hospital, then the therapy is evaluated by means of a whole body scan using SPECT/CT. Region of Interest (ROI) was carried out on the thyroid, stomach, liver, large intestine and bladder. On the third day the patient's dose rate value was below 70 μSv/h so that the patient could go home safely in accordance with radiation protection regulations. The average dose rate value for obese patients was higher compared to patients with low, normal and excess BMI. The high organ radiation count value for whole body SPECT/CT scan patients is caused by several factors such as the absorption of 131I by organs and the buildup of radioisotopes in organs.

Downloads

Download data is not yet available.

References

Kepmenkes RI. 2009. Keputusan Menteri Kesehatan Republik Indonesia Nomor 008/MENKES/SK/2009 tentang Standar Pelayanan Kedokteran Nuklir di Sarana Pelayanan Kesehatan.

Schmidbauer, B., Menhart, K., Hellwig, D., & Grosse, J. (2017). Differentiated Thyroid Cancer—Treatment: State of the Art. In International Journal of Molecular Sciences (Vol. 18, Issue 6). MDPI AG. https://doi.org/10.3390/ijms18061292 DOI: https://doi.org/10.3390/ijms18061292

Global Cancer Statistics. 2020. GLOBOCAN Estimates of Incidence and Mortality Worldwide for 36 Cancers in 185 Countries. A Cancer Journal for Clinicians, 71(3), 209–249. DOI: https://doi.org/10.3322/caac.21660

IAEA. (2009). Release of Patients After Radionuclide Therapy.

World Health Organization. Physical status: the use and interpretation of anthropometry. WHO, Technical Report Series No. 854, 1995.

Mutohar A., et al. 2017. Laju Paparan dan Dosis Radiasi dari Pasien Terapi Kelainan Kelenjar Tiroid dengan Pemberian Radiofarmaka Iodium-131. Semarang: Youngster Physics Journal.

Oh, J.-R., & Ahn, B.-C. 2012. False-Positive Uptake on Radioiodine Whole-Body Scintigraphy: Physiologic and Pathologic Variants Unrelated to Thyroid Cancer. Journal Nuclear Medicine.

Parthasarathy KL, Crawford ES. Treatment of thyroid carcinoma: emphasis on high-dose 131I outpatient therapy. J Nucl Med Technol. 2002 Dec;30(4):165-71.

Foroulis, C.N., & Zarogoulidis, P. 2012. Nuclear Medicine Imaging in the Evaluation of the Thyroid Nodule. In A. Margariti (Ed.), Thyroid Disorders: Focus on Hyperthyroidism (pp. 169-176). InTech.

Downloads

Published

21-07-2024

Issue

Section

Research Articles

How to Cite

Analysis of Radiation Dose Rate and Evaluation of Whole Body Scan SPECT/CT Images in Thyroid Carcinoma Radioablation Patients Using Radioisotope 131I. (2024). International Journal of Scientific Research in Science and Technology, 11(4), 135-143. https://doi.org/10.32628/IJSRST24114115

Similar Articles

1-10 of 64

You may also start an advanced similarity search for this article.